Georgia Cleanup Standards for Hydrocarbon Contaminated Groundwater

Product Parameter/ Constituent Lab Test Protocol & Number Detection Level Cleanup Level
Gasoline Benzene EPA 8021/8260

1.0µg/L

5µg/L (MCL)

Toluene EPA 8021/8260

1.0µg/L

1000µg/L (MCL)

Ethylbenzene EPA 8021/8260

1.0µg/L

700µg/L (MCL)

Xylenes EPA 8021/8260

1.0µg/L

10,000µg/L (MCL)

Diesel/Waste Oil PAH constituents EPA 8100, 8270, 8310

10µg/L

MCL levels

Note: Cleanup levels listed are MCLs. Georgia In-Stream Water Quality Standards apply when there is no point of groundwater withdrawal within the radii of concern. Risk-based, site-specific levels (ACLs) may be calculated and used as groundwater cleanup levels in certain circumstances.

Notification levels are any detectable amount.

Contact: Shaheer Muhanna, Technical Assistance Officer, Georgia Department of Natural Resources, 404-362-2687

E-mail: shaheer_muhanna@mail.dnr.state.ga.us

Web Site: http://www.dnr.state.ga.us