Illinois Cleanup Standards
for Hydrocarbon Contaminated Groundwater
|
Product |
Parameter/
Constituent |
Lab Test Protocol &
Number |
Detection Level |
Notification Level |
Action Level |
Cleanup Level |
|
Gasoline
|
Benzene |
* |
** |
any amount |
0.005mg/L |
site specific |
|
Ethylbenzene |
* |
** |
any amount |
0.7mg/L |
site specific |
|
Toluene |
* |
** |
any amount |
1.0mg/L |
site specific |
|
Xylenes (total) |
* |
** |
any amount |
10.0mg/L |
site specific |
|
Other petroleum
|
Naphthalene |
* |
** |
any amount |
0.14mg/L |
site specific |
|
Acenaphthene |
* |
** |
any amount |
0.42mg/L |
site specific |
|
Anthracene |
* |
** |
any amount |
2.1mg/L |
site specific |
|
Fluoranthene |
* |
** |
any amount |
0.28mg/L |
site specific |
|
Fluorene |
* |
** |
any amount |
0.28mg/L |
site specific |
|
Pyrene |
* |
** |
any amount |
0.21mg/L |
site specific |
|
Acenaphthylene |
* |
0.010mg/L |
any amount |
*** |
site specific |
|
Benzo(g,h,i)perylene |
* |
0.00076mg/L |
any amount |
*** |
site specific |
|
Phenanthrene |
* |
0.0064mg/L |
any amount |
*** |
site specific |
|
Benzo(a)anthracene |
* |
** |
any amount |
0.00013mg/L |
site specific |
|
Benzo(a)pyrene |
* |
** |
any amount |
0.0002mg/L |
site specific |
|
Benzo(b)fluoranthene |
* |
** |
any amount |
0.00018mg/L |
site specific |
|
Benzo(k)fluoranthene |
* |
** |
any amount |
0.00017mg/L |
site specific |
|
Chrysene |
* |
** |
any amount |
0.0015mg/L |
site specific |
|
Dibenzo(a,H)anthracene |
* |
** |
any amount |
0.0003mg/L |
site specific |
|
Indeno(1,2,3-cd)pyrene |
* |
** |
any amount |
0.00043mg/L |
site specific |
*Any
approved USEPA SW-846 method
**
Detection level is test specific unless ADL is given.
***
Any amount above ADL
Note: The
Agency has adopted Risk-Based Corrective Action (RBCA) Regulations to
determine cleanup objectives if action levels are exceeded.
35
Illinois Administrative Code Part 742, Tiered Approach to Corrective
Action Objectives (TACO) gives the owner/operator the option to decide if
the Tier 1 levels are the action levels or they may choose to calculate a
Tier 2or 3 cleanup objective and remediate to these levels if required.
Contact:
Eric Portz, Illinois Environmental Protection Agency, 217-782-4869
Web
Site:
http://www.ipcb.state.il.us/title35/g742.htm
Top
|