Florida Cleanup Standards
for Hydrocarbon Contaminated Groundwater
|
Parameter/Constituent2 |
Lab Test Protocol & Number |
Cleanup Level |
|
Benzene |
EPA 602, 624, 8021, 8260 |
1µg/L
|
|
Ethylbenzene |
EPA 602, 624, 8021, 8260 |
30µg/L
|
|
Toluene |
EPA 602, 624, 8021, 8260 |
40µg/L |
|
Total Xylenes |
EPA 602, 624, 8021, 8260 |
20µg/L |
|
MTBE |
EPA 602, 624, 8021, 8260 |
50µg/L
|
|
Acenaphthene |
EPA 610, 625, 8100, 8270 or 8310 |
20µg/L
|
|
Acenaphthylene |
EPA 610, 625, 8100, 8270 or 8310 |
210µg/L
|
|
Anthracene |
EPA 610, 625, 8100, 8270 or 8310 |
2100µg/L
|
|
Benzo(a)anthracene |
EPA 610, 625, 8100, 8270 or 8310 |
0.2µg/L
|
|
Benzo(a)pyrene |
EPA 610, 625, 8100, 8270 or 8310 |
0.2µg/L
|
|
Benzo(b)fluoranthene |
EPA 610, 625, 8100, 8270 or 8310 |
0.2µg/L
|
|
Benzo(g,h,i)perylene |
EPA 610, 625, 8100, 8270 or 8310 |
210µg/L
|
|
Benzo(k)fluoranthene |
EPA 610, 625, 8100, 8270 or 8310 |
0.5µg/L
|
|
Chrysene |
EPA 610, 625, 8100, 8270 or 8310 |
4.8µg/L
|
|
Dibenzo(a,h)anthracene |
EPA 610, 625, 8100, 8270 or 8310 |
0.2µg/L
|
|
Fluoranthene |
EPA 610, 625, 8100, 8270 or 8310 |
280µg/L
|
|
Fluorene |
EPA 610, 625, 8100, 8270 or 8310 |
280µg/L
|
|
Indeno(1,2,3-c,d)pyrene |
EPA 610, 625, 8100, 8270 or 8310 |
0.2µg/L
|
|
Naphthalene |
EPA 610, 625, 8100, 8270 or 8310 |
20µg/L
|
|
1-Methylnaphthalene |
EPA 610, 625, 8100, 8270 or 8310 |
20µg/L
|
|
2-Methylnaphthalene |
EPA 610, 625, 8100, 8270 or 8310 |
20µg/L
|
|
Phenanthrene |
EPA 610, 625, 8100, 8270 or 8310 |
210µg/L
|
|
Pyrene |
EPA 610, 625, 8100, 8270 or 8310 |
210µg/L
|
|
1,2-dichloroethane |
EPA 601, 624, 8021 or 8260 |
3µg/L |
|
1,2-dibromoethane (EDB) |
EPA 6011 or 504 or 8011 |
0.02µg/L
|
|
Arsenic |
EPA 200.7, 206.2, 206.3, 6010, 7060 or 7061 |
50µg/L
|
|
Cadmium |
EPA 200.7, 213.1, 213.2 6010, 7130 or 7131 |
5µg/L
|
|
Chromium |
EPA 200.7, 213.2, 6010 or 7191 |
100µg/L
|
|
Lead |
EPA 200.7, 200.8, 239.2, 6010 or 7421 |
15µg/L
|
|
TRPHs |
FL-PRO |
5000µg/L
|
Note:
The Detection Limits shall meet the specified cleanup target levels.
1
with electron capture detector substituted for electrolytic conductivity
detector and 2-column confirmation
Contact:
Thomas Conrardy,
Florida Department of Environmental Protection, 850-245-8899
Web Site:
http://www.dep.state.fl.us/dwm/programs/pcp
E-mail:
tom.conrardy@dep.state.fl.us