Michigan Cleanup Standards
for Hydrocarbon Contaminated Groundwater
|
Product |
Parameter/ Constituent |
Lab Test Protocol &
Number |
Detection Level |
Notification Level |
Action Level |
Cleanup Criteria
Residential |
|
Residential/Industrial-Commercial |
|
Gasoline
|
Benzene(c) |
EPA 8260, 8021, Applicable 500 Series Drinking Water Methods,
Applicable CLP Methods, Applicable Standard Method Procedures |
1µg/L |
> Residential
Criterion |
same as
Cleanup Criteria |
5/5µg/L |
|
Toluene(d) |
EPA 8260, 8021, Applicable 500 Series Drinking Water Methods,
Applicable CLP Methods, Applicable Standard Method Procedures |
1µg/L |
> Residential
Criterion |
same as
Cleanup Criteria |
140/140µg/L |
|
Ethylbenzene(d) |
EPA 8260, 8021, Applicable 500 Series Drinking Water Methods,
Applicable CLP Methods, Applicable Standard Method Procedures |
1µg/L |
> Residential
Criterion |
same as
Cleanup Criteria |
18/18µg/L |
|
Xylenes(d) |
EPA 8260, 8021, Applicable 500 Series Drinking Water Methods,
Applicable CLP Methods, Applicable Standard Method Procedures |
3µg/L |
> Residential
Criterion |
same as
Cleanup Criteria |
35/35µg/L |
|
Premium Gas |
MTBE(b) |
EPA 8021, 8240A, 8260A |
5µg/L* |
> Residential
Criterion |
same as
Cleanup Criteria |
40/40µg/L |
|
Leaded Gas |
Lead(a) |
8 listed methods |
3µg/L |
> Residential
Criterion |
same as
Cleanup Criteria |
4/4µg/L |
|
Diesel
|
BTEX |
EPA 8260, 8021, Applicable 500 Series Drinking Water Methods,
Applicable CLP Methods, Applicable Standard Method Procedures |
|
> Residential Criterion |
same as Cleanup Criteria |
Same as above |
|
PAHs * |
EPA 8270, 8041, Applicable 500 Series Drinking Water Methods,
Applicable CLP Methods, Applicable Standard Method Procedures |
1-5µg/L |
> Residential
Criterion |
same as
Cleanup Criteria |
varies by chemical |
a Health based
drinking water value.
b Aesthetic drinking
water value.
c State drinking water
standard
d Groundwater Surface
Water Interface Criterion (protection of surface water)
* Acceptable methods
for determining PAH compounds are below MDLs of OM#6 when neither
petroleum hydrocarbons nor PAHs are present. If present, other PAH methods
such as 8270 or 8310 should be used.
Note:
Alternative Cleanup
Criteria may be available under certain circumstances.
Contact:
Christine Flaga,
Michigan Department of Environmental Quality, Environmental Response
Division, 517-373-0160
E-mail:
flagac@michigan.gov
Top
|