Florida Cleanup Standards
for Hydrocarbon Contaminated Groundwater
|
Parameter/Constituent2
|
Lab
Test Protocol & Number
|
Cleanup
Level
|
|
Benzene
|
EPA
602, 624, 8021, 8260
|
1µg/L
|
|
Ethylbenzene
|
EPA
602, 624, 8021, 8260
|
30µg/L
|
|
Toluene
|
EPA
602, 624, 8021, 8260
|
40µg/L
|
|
Total
Xylenes
|
EPA
602, 624, 8021, 8260
|
20µg/L
|
|
MTBE
|
EPA
602, 624, 8021, 8260
|
50µg/L
|
|
Acenaphthene
|
EPA
610, 625, 8100, 8270 or 8310
|
20µg/L
|
|
Acenaphthylene
|
EPA
610, 625, 8100, 8270 or 8310
|
210µg/L
|
|
Anthracene
|
EPA
610, 625, 8100, 8270 or 8310
|
2100µg/L
|
|
Benzo(a)anthracene
|
EPA
610, 625, 8100, 8270 or 8310
|
0.2µg/L
|
|
Benzo(a)pyrene
|
EPA
610, 625, 8100, 8270 or 8310
|
0.2µg/L
|
|
Benzo(b)fluoranthene
|
EPA
610, 625, 8100, 8270 or 8310
|
0.2µg/L
|
|
Benzo(g,h,i)perylene
|
EPA
610, 625, 8100, 8270 or 8310
|
210µg/L
|
|
Benzo(k)fluoranthene
|
EPA
610, 625, 8100, 8270 or 8310
|
0.5µg/L
|
|
Chrysene
|
EPA
610, 625, 8100, 8270 or 8310
|
4.8µg/L
|
|
Dibenzo(a,h)anthracene
|
EPA
610, 625, 8100, 8270 or 8310
|
0.2µg/L
|
|
Fluoranthene
|
EPA
610, 625, 8100, 8270 or 8310
|
280µg/L
|
|
Fluorene
|
EPA
610, 625, 8100, 8270 or 8310
|
280µg/L
|
|
Indeno(1,2,3-c,d)pyrene
|
EPA
610, 625, 8100, 8270 or 8310
|
0.2µg/L
|
|
Naphthalene
|
EPA
610, 625, 8100, 8270 or 8310
|
20µg/L
|
|
1-Methylnaphthalene
|
EPA
610, 625, 8100, 8270 or 8310
|
20µg/L
|
|
2-Methylnaphthalene
|
EPA
610, 625, 8100, 8270 or 8310
|
20µg/L
|
|
Phenanthrene
|
EPA
610, 625, 8100, 8270 or 8310
|
210µg/L
|
|
Pyrene
|
EPA
610, 625, 8100, 8270 or 8310
|
210µg/L
|
|
1,2-dichloroethane
|
EPA
601, 624, 8021 or 8260
|
3µg/L
|
|
1,2-dibromoethane
(EDB)
|
EPA
6011 or 504 or 8011
|
0.02µg/L
|
|
Arsenic
|
EPA
200.7, 206.2, 206.3, 6010, 7060 or 7061
|
50µg/L
|
|
Cadmium
|
EPA
200.7, 213.1, 213.2 6010, 7130 or 7131
|
5µg/L
|
|
Chromium
|
EPA
200.7, 213.2, 6010 or 7191
|
100µg/L
|
|
Lead
|
EPA
200.7, 200.8, 239.2, 6010 or 7421
|
15µg/L
|
|
TRPHs
|
FL-PRO
|
5000µg/L
|
Note:
The Detection Limits shall meet the specified cleanup target levels.
1 with
electron capture detector substituted for electrolytic conductivity
detector and 2-column confirmation
Contact:
Thomas Conrardy, Florida Department of
Environmental Protection, 850-488-3935
Web Site: http://www.dep.state.fl.us/dwm/programs/pcp
E-mail: tom.conrardy@dep.state.fl.us
Top
|