Mississippi Cleanup
Standards for Hydrocarbon Contaminated Groundwater
Underground Storage Tank Typical
Cleanup Levels
|
|
The
following cleanup levels are typically used if there are no
sensitive environmental receptors such as public water wells,
geologic areas, vapors in a home, etc.
|
|
Substance
in Tank
|
Media
|
Typical
Cleanup Levels
|
|
Gasoline
|
Soil
Water
|
110
mg/kg BTEX*
18
mg/L BTEX*
|
|
Diesel,
waste oil, or kerosene
|
Soil
Water
|
PAH**
See table below(for both soil and water)
|
|
*BTEX
= Benzene, Toluene, Ethylbenzene, and Xylenes (EPA 8021B or 8260B)
|
|
**PAH
= Polynuclear Aromatic Hydrocarbons (EPA 8100, 8270C, or 8310)
|
Cleanup Levels for Polynuclear
Aromatic Hydrocarbons
|
|
Constituent
|
Soil
Level(mg/kg)
|
Groundwater
Level(mg/L)
|
|
Acenaphthene
|
>28
|
2.2
|
|
Acenaphthylene
|
>9.5
|
0.15
|
|
Anthracene
|
>0.66
|
>0.045
|
|
Benzo
(a) Anthracene
|
1.0
|
0.00012
|
|
Benzo
(b) Fluoranthene
|
0.42
|
0.00012
|
|
Benzo
(k) Fluoranthene
|
>2.4
|
0.0012
|
|
Benzo
(g, h, i ) Perylene
|
>1.1
|
>0.0007
|
|
Benzo
(a) Pyrene
|
1.3
|
0.0002
|
|
Chrysene
|
0.26
|
0.0002
|
|
Dibenzo
(a,h) Anthracene
|
0.056
|
0.00001
|
|
Fluoranthene
|
>7.9
|
>0.21
|
|
Fluorene
|
>12
|
1.5
|
|
Indeno
(1,2,3,c,d) Pyrene
|
26.0
|
0.00012
|
|
Naphthalene
|
9.8
|
0.73
|
|
Phenanthrene
|
>23
|
1.1
|
|
Pyrene
|
>6.1
|
0.16
|
* If no sensitive environmental receptors are
present.
Contact: Martha
Martin, Mississippi Underground Storage Tank Division, 601-961-5171
Top
|