West Virginia Cleanup
Standards for Hydrocarbon Contaminated Groundwater
|
Product
|
Parameter/
Constituent
|
Lab
Test Protocol & Number
|
Detection
Level
|
Notification
Level
|
Action
Level
|
Cleanup
Level
|
|
Gasoline
|
Benzene
|
EPA
8021
|
1µg/L
|
any
amount
|
5µg/L
|
5µg/L
|
|
Toluene
|
EPA
8021
|
1µg/L
|
any
amount
|
1000µg/L
|
1000µg/L
|
|
Ethylbenzene
|
EPA
8021
|
1µg/L
|
any
amount
|
700µg/L
|
700µg/L
|
|
Xylenes
|
EPA
8021
|
1µg/L
|
any
amount
|
10,000µg/L
|
10,000µg/L
|
|
TPH
|
EPA
8015
|
0.5mg/L
|
any
amount
|
|
site
specific
|
|
Diesel
|
Benzene
|
EPA
8021
|
1µg/L
|
any
amount
|
5µg/L
|
5µg/L
|
|
Toluene
|
EPA
8021
|
1µg/L
|
any
amount
|
1000µg/L
|
1000µg/L
|
|
Ethylbenzene
|
EPA
8021
|
1µg/L
|
any
amount
|
700µg/L
|
700µg/L
|
|
Xylenes
|
EPA
8021
|
1µg/L
|
any
amount
|
10,000µg/L
|
10,000µg/L
|
|
TPH
|
Modified
EPA 8015, GRO & DRO
|
0.5mg/L
|
any
amount
|
|
site
specific
|
Note:
Some leaking underground storage tank sites may
qualify for West Virginia's voluntary cleanup program, which utilizes Risk
Based Corrective Action (RBCA).
Contact:
Mike Sutphin, West Virginia Department of
Environmental Protection, 304-558-2508
E-mail:
msutphin@mail.dep.state.wv.us
Top
|