Mississippi
Cleanup Standards for Hydrocarbon Contaminated Soil
|
Underground Storage Tank Typical Cleanup
Levels |
|
The following cleanup
levels are typically used if there are no sensitive environmental
receptors such as public water wells, geologic areas, vapors in a
home, etc. |
|
Substance in Tank |
Media |
Typical Cleanup Levels |
|
Gasoline |
Soil
Water |
110 mg/kg BTEX*
18 mg/L BTEX* |
|
Diesel, waste oil, or
kerosene |
Soil
Water |
PAH** See table
below(for both soil and water) |
|
*BTEX = Benzene,
Toluene, Ethylbenzene, and Xylenes (EPA 8021B or 8260B) |
|
**PAH = Polynuclear
Aromatic Hydrocarbons (EPA 8100, 8270C, or 8310) |
|
Cleanup Levels for Polynuclear Aromatic
Hydrocarbons |
|
Constituent |
Soil Level(mg/kg) |
Groundwater Level(mg/L) |
|
Acenaphthene |
>28 |
2.2 |
|
Acenaphthylene |
>9.5 |
0.15 |
|
Anthracene |
>0.66 |
>0.045 |
|
Benzo (a) anthracene |
1.0 |
0.00012 |
|
Benzo (b) fluoranthene |
0.42 |
0.00012 |
|
Benzo (k) fluoranthene |
>2.4 |
0.0012 |
|
Benzo (g, h, i )
perylene |
>1.1 |
>0.0007 |
|
Benzo (a) pyrene |
0.077 |
0.000012 |
|
Chrysene |
0.096 |
0.000074 |
|
Dibenzo (a,h)
anthracene |
0.056 |
0.000012 |
|
Fluoranthene |
>7.9 |
>0.21 |
|
Fluorene |
>12 |
1.5 |
|
Indeno (1,2,3,c,d)
pyrene |
26.0 |
0.00012 |
|
Naphthalene |
9.8 |
0.73 |
|
Phenanthrene |
>23 |
1.1 |
|
Pyrene |
>6.1 |
0.16 |
* If
no sensitive environmental receptors are present.
Contact:
Martha Martin, Mississippi Underground Storage Tank Division, 601-961-5171
Top
|