Wyoming Clean-up
Standards for Hydrocarbon Contaminated Soil
|
Product |
Parameter/
Constituent |
Lab Test Protocol &
Number |
Detection Level |
Notification Level |
Action Level |
Cleanup Level |
|
Fuel
Tanks |
BTEX |
EPA 5030B/8021B or
5030B/8260B |
* |
any amount |
** |
** |
|
MTBE |
EPA 5030B/8260B |
* |
any amount |
** |
** |
|
Total Lead
|
EPA 3020A/7421 |
* |
any amount |
** |
** |
|
TPH |
EPA 8015B GRO C6-C10 |
* |
any amount |
>28mg/kg |
28 - 15,600mg/kg
(site specific) |
|
TPH |
EPA 8015B DRO
C10-C32 |
* |
any amount |
>2300mg/kg |
2300mg/kg |
|
Naphthalene |
EPA 5030B/8021B or
5030B/8260B |
* |
any amount |
** |
** |
|
Waste
Oil
Tanks |
BTEX |
EPA 5030B/8021B or
5030B/8260B |
* |
any amount |
** |
** |
|
TPH |
EPA 8015B DRO C10 –
C32 |
* |
any amount |
>2300mg/kg |
2300mg/kg |
|
Naphthalene |
EPA 5030B/8021B or
5030B/8260B |
* |
any amount |
** |
** |
|
Total Lead |
EPA 3020A/7421 or
6010B |
* |
any amount |
** |
** |
|
Total Cadmium |
EPA 3020A/7131A or
6010B |
* |
any amount |
** |
** |
|
Total Chromium |
EPA 3020A/7191 or
6010B |
* |
any amount |
** |
** |
*Test Specific.
** Site Specific.
Note: Site
Specific soil cleanup levels for organic compounds and metals are
determined from an environmental fate/transport environmental risk
assessment model contained in the Wyoming Water Quality Rules and
Regulations, Chapter XVII, Underground Storage Tanks, Appendix A.
Procedures for Establishing Environmental Restoration Standards for
Leaking Underground Storage Tank Remediation Actions. Model is similar
to ASTM RBCA.
Contact: LeRoy
Feusner, Department of Environmental Quality, 307-777-7096
E-mail:
lfeusn@missc.state.wy.us
Top
|