Wyoming Clean-up Standards for Hydrocarbon Contaminated Soil

Product

Parameter/ Constituent

Lab Test Protocol & Number

Detection Level

Notification Level

Action Level

Cleanup Level

Fuel

 

Tanks

BTEX

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

MTBE

EPA 5030B/8260B

*

any amount

**

**

Total Lead

EPA 3020A/7421

*

any amount

**

**

TPH

EPA 8015B GRO C6-C10

*

any amount

>28mg/kg

28 - 15,600mg/kg

(site specific)

TPH

EPA 8015B DRO C10-C32

*

any amount

>2300mg/kg

2300mg/kg

Naphthalene

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

Waste

Oil

Tanks

BTEX

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

TPH

EPA 8015B DRO C10 – C32

*

any amount

>2300mg/kg

2300mg/kg

Naphthalene

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

Total Lead

EPA 3020A/7421 or 6010B

*

any amount

**

**

Total Cadmium

EPA 3020A/7131A or 6010B

*

any amount

**

**

Total Chromium

EPA 3020A/7191 or 6010B

*

any amount

**

**

*Test Specific.

** Site Specific.

Note: Site Specific soil cleanup levels for organic compounds and metals are determined from an environmental fate/transport environmental risk assessment model contained in the Wyoming Water Quality Rules and Regulations, Chapter XVII, Underground Storage Tanks, Appendix A. Procedures for Establishing Environmental Restoration Standards for Leaking Underground Storage Tank Remediation Actions. Model is similar to ASTM RBCA.

Contact: LeRoy Feusner, Department of Environmental Quality, 307-777-7096

E-mail: lfeusn@missc.state.wy.us