| Michigan
Cleanup Standards for Hydrocarbon Contaminated Soil
|
Product |
Parameter/ Constituent |
Lab Test Protocol & Number |
Detection Level |
Notification Level |
Action Level |
Cleanup Criteria Residential |
|
Gasoline |
Benzene |
EPA SW 8260, 8021 |
10/50µg/kg |
>Residential
Criterion |
100µg/kg |
100µg/kg |
|
Toluene |
EPA SW 8260, 8021 |
10/100µg/kg |
>Residential
Criterion |
2,800µg/kg |
2,800µg/kg |
|
Ethylbenzene |
EPA SW 8260, 8021 |
10/50µg/kg |
>Residential
Criterion |
360µg/kg |
360µg/kg |
|
Xylenes |
EPA SW 8260, 8021 |
30/150µg/kg |
>Residential
Criterion |
700µg/kg |
700µg/kg |
|
Premium Gas |
MTBE |
EPA SW 8260, 8021 |
100/250µg/kg |
>Residential
Criterion |
800µg/kg |
800µg/kg |
|
Leaded Gas
|
Lead |
EPA 6010, 6020, 200.7, 200.8, 200.9, Applicable CLP Methods |
1,000µg/kg |
>Residential
Criterion |
400,000ug/kg
|
400,000ug/kg
|
|
PAHs |
EPA 8270, 8310, Applicable CLP Methods |
330µg/kg |
>Residential
Criterion |
same as cleanup
criteria |
varies by chemical |
Note:
Waste oil samples need to be tested for other metals and organic solvents.
Call MDEQ for information. Alternative cleanup criteria may be available
under certain circumstances.
Contact:
Christine Flaga,
Michigan Department of Environmental Quality, Environmental Response
Division, 517-373-0160
E-mail:
flagac@michigan.gov
Top
|