Wyoming Clean-up Standards for Hydrocarbon Contaminated Soil

Product

Parameter/ Constituent

Lab Test Protocol & Number

Detection Level

Notification Level

Action Level

Cleanup Level

Gasoline

BTEX

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

MTBE

EPA 5030B/8260B

*

any amount

**

**

Total Lead

EPA 3020A/7421

*

any amount

**

**

TPH

EPA 8015B GRO C6-C10

*

any amount

>30mg/kg

30mg/L gw <50ft

>100mg/kg

100mg/L gw >50ft

Fuel Oils

BTEX

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

TPH

EPA 8015B DRO C10-C32

*

any amount

>100mg/kg

100mg/kg

Lubricating Oils

BTEX

EP5030B/8021B or 5030B/8260B A

*

any amount

**

**

TPH

EPA 8015B DRO C10-C32

*

any amount

>100mg/kg

100mg/kg

Waste Oil

BTEX

EPA 5030B/8021B or 5030B/8260B

*

any amount

**

**

TPH

EPA 8015B DRO C10 – C32

*

any amount

>100mg/kg

100mg/kg

Total Lead

EPA 3020A/7421

*

any amount

**

**

Total Cadmium

EPA 3020A/7131A

*

any amount

**

**

Total Chromium

EPA 3020A/7191

*

any amount

**

**

*Test Specific.

** Site Specific.

Note: Site Specific soil cleanup levels for organic compounds and metals are determined from an environmental fate/transport environmental risk assessment model contained in the Wyoming Water Quality Rules and Regulations, Chapter XVII, Underground Storage Tanks, Appendix A. Procedures for Establishing Environmental Restoration Standards for Leaking Underground Storage Tank Remediation Actions. Model is similar to ASTM RBCA.

Contact: LeRoy Feusner, Department of Environmental Quality, 307-777-7096

E-mail: lfeusn@missc.state.wy.us



Top

Design and hosting by Web Studio Designs & Pioneer Host Internet Solutions
 
Copyright © 2000 The Association for the Environmental Health of Soils
150 Fearing Street · Amherst, MA 01002
Phone: 413.549.5170
Fax: 413.549.0579

E-mail: info@aehs.com